Precautions and Operating Procedures for Asphalt Mixture Compaction Machines

2022-01-07


  Precautions for Using the Asphalt Mixture Compaction Tester
  1. The counter counts in a forward-counting manner.
  2. The next time you strike, first press the reset button and then the start button.
  3. When compaction is in progress and you need to stop the machine or if the machine malfunctions, press the stop button to halt the compaction apparatus.
  4. The chain tension should be checked regularly, and adjusted if its sag exceeds 10 mm.
  5. Do not start the compaction machine when it is not loaded with mixtures. When not in use, place cotton yarn or shredded paper inside the test mold.
  6. Lubricate the chain and the sliding parts of the weight regularly.
  7. After each compaction is completed, the test mold, compaction punch, and steel plate platform should be cleaned immediately.
  8. The tension between the steel plate platform and the concrete base should be checked regularly.

  Operating Procedures for Asphalt Mixture Compaction Tester
  1. First, connect the three plugs at the back of the cabinet properly. The “motor” should be connected to the motor input port on the cabinet, the “non-contact proximity switch” should be connected to the counting port, and the “power supply” should be connected to the power port. At the same time, make sure the neutral wire is properly connected.
  2. After completing the above steps, toggle the “Preset” dial to set the desired number of compaction cycles, ranging from 1 to 99. Once the power switch is turned on, the digital display on the panel will show “00,” and the power indicator light will illuminate.
  3. Press the start button to activate the controller; the status light will illuminate, and the digital display will show “00.” The motor will begin rotating, raising the hammer to compact the material. Each time the hammer strikes, the digital display will increment by one. Once the preset number of strikes is reached, the motor will stop, and the indicator light will turn off.
  Press the Pause button to stop the operation; the status indicator will turn off. Press the Start button again to resume normal operation. If any abnormal situation occurs during operation, press the Pause button. At this time, the digital display will show the number of times the button has been pressed. After completing one experiment, first press the Reset button, then press the Start button.

 

Relevant Information


The main advantages of the penetration tester are:

The main advantages of the penetration tester are:

2023-11-02

The working principle of the compaction apparatus mainly includes the following points:

The working principle of the compaction apparatus mainly includes the following points:

2023-10-23

What is a compaction tester?

The compaction instrument is a device used to measure the bearing capacity of bored pile foundations. Its main features are as follows:

2023-10-13